Dryer Control System Using the 8086 Microprocessor
A dryer controller written in 8086 assembly: it keeps temperature at a setpoint and sounds an alarm when pressure goes too high.
Complete circuit and program run in Proteus.
15 simulated cases at setpoints of 30 °C and 100 kPa; heater and alarm switched as specified in each case.
No physical hardware was built.
Interfacing
An LM35 temperature sensor and an MPX4115A pressure sensor produce analog voltages that an ADC0804 converts to 8-bit values. The 8255 PPI, configured in Mode 0, handles all I/O: Port A drives the seven-segment display, Port B reads the ADC, and Port C reads the push buttons and drives the heater relay and buzzer.

Control logic
The main loop reads the buttons, samples both sensors and compares them with the setpoints. The heater turns on while temperature is below the setpoint (CMP and JB) and the buzzer sounds while pressure is above its limit (CMP and JA). Inputs and outputs share Port C, so outputs are written through a masked copy (OUT_IMAGE) to avoid disturbing button reads.
Simulation results
| No. | Temperature (°C) | Pressure (kPa) | Heater | Buzzer |
|---|---|---|---|---|
| 1 | 22 | 85 | ON | OFF |
| 2 | 25 | 95 | ON | OFF |
| 3 | 28 | 98 | ON | OFF |
| 4 | 29 | 102 | ON | ON |
| 5 | 30 | 90 | OFF | OFF |
| 6 | 30 | 105 | OFF | ON |
| 7 | 32 | 88 | OFF | OFF |
| 8 | 33 | 110 | OFF | ON |
| 9 | 35 | 97 | OFF | OFF |
| 10 | 36 | 115 | OFF | ON |
| 11 | 27 | 92 | ON | OFF |
| 12 | 26 | 108 | ON | ON |
| 13 | 31 | 99 | OFF | OFF |
| 14 | 34 | 101 | OFF | ON |
| 15 | 24 | 120 | ON | ON |
Shown
- Heater on/off around the temperature setpoint
- Alarm and automatic recovery for over-pressure
Limits and next steps
- Simulation only; real sensor noise and relay timing not tested
- On–off control only; no hysteresis or PID